| Function 
                                        characteristic: | 
                                    
                                     
                                      |     
                                        Based on infrared technology automatic 
                                        control product, when some people enter 
                                        the switch induces the scope, the special-purpose 
                                        sensor surveys the human body infrared 
                                        spectrum the change, the switch automatic 
                                        connection load, the human does not leave 
                                        the induction scope, the switch continually 
                                        puts through; After the human leaves, 
                                        switch time delay automatic shut-off load.Is 
                                        bright the human to the lamp, the human 
                                        extinguishes to the lamp, kind convenient, 
                                        safe energy conservation. | 
                                    
                                     
                                      | Bipolarity 
                                        design:With ordinary wall switch 
                                        (three connections), load capacity 200W | 
                                    
                                     
                                      | Completely 
                                        automatic induction:The human comes 
                                        the switch to put through immediately, 
                                        after the human leaves the time delay 
                                        automatic shut-off. | 
                                    
                                     
                                      | Relay 
                                        switch:Connection load strength, 
                                        relay switch service life 100,000 times. | 
                                    
                                     
                                      | Automatic 
                                        light measuring:Light strong when 
                                        does not induce (exwork establishment), 
                                        has the photosensitivity adjustment (also 
                                        to be possible to adjust under random 
                                        light induces or the all-weather induces). | 
                                    
                                     
                                      | Automatic 
                                        stochastic time delay(May sequential time 
                                        delay way): The human in the induction 
                                        scope activity, the switch always puts 
                                        through, leaves the only then automatic 
                                        shut-off after the human. Has in addition 
                                        may not the sequential time delay way 
                                        (be possible to elect). | 
                                    
                                     
                                      | Delay 
                                        time adjustable:16 seconds - 350 
                                        seconds (also may act according to customer 
                                        request making to order, making to order 
                                        scope zero several seconds to 30 minutes). | 
                                    
                                     
                                      | Ultra 
                                        low power loss:Switch own power 
                                        loss<0.016W/h 
                                        (year consumes electricity< 0.14 kwh), 
                                        compared to other brand similar product 
                                        electricity saving.. | 
                                    
                                     
                                      | Anti-radar 
                                        function:Ad hoc anti-radar component, 
                                        but prevented effectively the thunder 
                                        and lightning and so on the instantaneous 
                                        high pressure the harm which creates to 
                                        the switch. | 
                                    
                                     
                                      | Fire 
                                        emergency function:When 
                                        comes across the fire and so on the emergency 
                                        case, the use “the long-distance fire 
                                        control” the function causes all lamp 
                                        compulsion to lighten, guarantee emergency 
                                        case illumination.(Must lay down a fire 
                                        pilot wire specially) | 
                                    
                                     
                                      | Electrical 
                                        parameter: | 
                                    
                                     
                                       
                                          
                                             
                                              |   Induction 
                                                  way  | 
                                                Passive 
                                                  form  | 
                                                Working 
                                                  voltage  | 
                                                180V-AC240V(50Hz/60Hz)  | 
                                             
                                             
                                              |   Induction 
                                                  principle  | 
                                                Human body 
                                                  infrared  | 
                                                Own power  | 
                                                <0.016W/h  | 
                                             
                                             
                                              Induction 
                                                  distance  | 
                                              7 meters  | 
                                              Load capacity  | 
                                              200W  | 
                                             
                                             
                                              Induction 
                                                  angle  | 
                                              140 degrees 
                                                  coning angles  | 
                                              Load scope  | 
                                              Each kind 
                                                  of load  | 
                                             
                                             
                                              The light 
                                                  controls the induction  | 
                                              5LUX-500LUX 
                                                  (adjustable)  | 
                                              Ambient 
                                                  temperature  | 
                                              -20℃—+50℃  | 
                                             
                                          
                                          | 
                                    
                                     
                                      | Applicable 
                                        scope: | 
                                    
                                     
                                      |     
                                        Place and so on corridor, corridor, bathroom, 
                                        basement, warehouse, garage automatic 
                                        illuminations, exhaust fan automatic convulsion 
                                        as well as other electric appliance functions 
                                        and so on automatic control, simultaneously 
                                        available in security and so on uses. | 
                                    
                                     
                                      | Wiring graphical 
                                        representation: | 
                                    
                                     
                                       | 
                                    
                                     
                                      | Induction 
                                        scope graphical representation: | 
                                    
                                     
                                       
                                          
                                             
                                               
                                                   
                                                  (Wall installs graphical 
                                                  representation)  | 
                                                    | 
                                                (Attracts 
                                                  goes against installs graphical 
                                                  representation) 
                                                  | 
                                             
                                          
                                          | 
                                    
                                     
                                      | Electrical 
                                        energy statement of profit and loss: (Reference) |