                                        Function 
                                          characteristic: | 
                                      
                                       
                                        |   | 
                                           
                                            Automatic 
                                          control products based on infrared technology, 
                                          when people go into the switch sensing 
                                          range, special sensors to detect changes 
                                          in the infrared spectrum, the switch 
                                          automatically connected to the load, 
                                          do not leave the sensing range of activities, 
                                          the switch will continue to connect; 
                                          left, the switch delay automatically 
                                          shut down the load. Lights away from 
                                          the lights go out, people, friendly 
                                          and convenient, safe and energy saving. | 
                                      
                                       
                                        |   | 
                                        Bipolar 
                                          design: (three-wire connection), 
                                          the load capacity resistive 1000W, emotional 
                                          400W | 
                                      
                                       
                                        |   | 
                                        Switch 
                                          to the automatic induction: people 
                                          are now connected to automatically shut 
                                          down, leave the delay. | 
                                      
                                       
                                        |   | 
                                        Relay 
                                          Switch: Switch on the load power, 
                                          long life. | 
                                      
                                       
                                        |   | 
                                        Load: 
                                          incandescent, energy saving lamps, 
                                          fluorescent lamps, LED lamps and other 
                                          lamps and appliances. | 
                                      
                                       
                                        |   | 
                                        Automatic 
                                          Metering: For light control standard 
                                          matte-control functions for all-weather 
                                          sensor can be customized. | 
                                      
                                       
                                        |   | 
                                        Automatic 
                                          random delay (continuous delayed mode): 
                                          in the sensing range of activities, 
                                          the switch is always connected, and 
                                          automatically shut down until after 
                                          the people left. (Note: in the sensing 
                                          range of inactivity after a delay turn 
                                          off automatically) | 
                                      
                                       
                                        |   | 
                                        Delay 
                                          time: 16 seconds -180 seconds 
                                          adjustable (according to customer request 
                                          making to order, customized range of 
                                          zero seconds to 30 minutes) | 
                                      
                                       
                                        |   | 
                                        Triggering 
                                          way:May trigger continuously, 
                                          cannot trigger continuously. (May jump 
                                          line choice) | 
                                      
                                       
                                        |   | 
                                        Mine 
                                          functions: Special lightning 
                                          protection devices, can effectively 
                                          prevent the damage of lightning and 
                                          other high-voltage transient caused 
                                          by the switch. | 
                                      
                                       
                                        |   | 
                                        Electrical 
                                          parameter: | 
                                      
                                       
                                        |   | 
                                         
                                            
                                               
                                                |   Induction 
                                                    way  | 
                                                  Passive 
                                                    form  | 
                                                  Working 
                                                    voltage  | 
                                                   
                                                    180V-AC240V(50Hz/60Hz)
  | 
                                               
                                               
                                                |   Induction 
                                                    principle  | 
                                                  Human body 
                                                    infrared  | 
                                                  Biggest 
                                                    power loss  | 
                                                  <0.016W 
                                                    | 
                                               
                                               
                                                Induction 
                                                    distance  | 
                                                5-8 meters  | 
                                                Load capacity  | 
                                                Inductive 
                                                    load 400W resistive load 1000W  | 
                                               
                                               
                                                Induction 
                                                    angle  | 
                                                140 degrees 
                                                    coning angles  | 
                                                Load scope  | 
                                                Various 
                                                    types of load  | 
                                               
                                               
                                                The light 
                                                    controls the induction  | 
                                                 Standard 
                                                    light control function, the 
                                                    need can be customized   | 
                                                Ambient 
                                                    temperature  | 
                                                -20℃—+50℃  | 
                                               
                                            
                                            | 
                                      
                                       
                                        |   | 
                                        Applicable 
                                          scope: | 
                                      
                                       
                                        |   | 
                                            
                                          Hallway, corridor, bathroom, basement, 
                                          warehouse, garage and other places of 
                                          automatic lighting, automatic ventilation 
                                          of the exhaust fan and other electrical 
                                          automatic control and other functions 
                                          can be used for security and other purposes. | 
                                      
                                       
                                        |   | 
                                        Wiring 
                                          graphical representation: | 
                                      
                                       
                                        |   | 
                                          | 
                                      
                                       
                                        |   | 
                                        Induction 
                                          scope graphical representation: | 
                                      
                                       
                                        |   | 
                                         
                                            
                                               
                                                 
                                                     
                                                    (Wall installs graphical 
                                                    representation)   | 
                                                      | 
                                                  (Attracts 
                                                    goes against installs graphical 
                                                    representation) 
                                                    | 
                                               
                                            
                                             |