| Function 
                                        characteristic: | 
                                    
                                     
                                          
                                        Products based on infrared technology, 
                                        automatic control, when people go into 
                                        the switch sensing range, special sensors 
                                        to detect changes in the infrared spectrum, 
                                        automatically output high, people do not 
                                        leave the sensing range of activities 
                                        will continue to output high; to leave.switch 
                                        delay is automatically shut down the load. 
                                        High sensitivity, reliability, and is 
                                        widely used in various auto-sensing electrical 
                                        equipment. 
                                        Delay time: according to customer request 
                                        making to order, made ??the scope of a 
                                        few tenths to 30 minutes. electric appliance 
                                        equipment. | 
                                    
                                     
                                      | Delay 
                                        time:Also may act according to 
                                        customer request making to order, making 
                                        to order scope zero several seconds to 
                                        30 minutes. | 
                                    
                                     
                                      | Ultra 
                                        low power loss:Switch own power 
                                        loss< 0.00005W. | 
                                    
                                     
                                      | Wide 
                                        voltage design:3.3-4 .5 VDC (can 
                                        be customized operating voltage :3.3-24VDC) | 
                                    
                                     
                                      | Has 
                                        the induction blocking time: The 
                                        induction module (high level turns low 
                                        level) after each induction output, may 
                                        follow close on is establishing a blocking 
                                        time section, the inductor does not accept 
                                        any induction signal in this time compartment.This 
                                        function may realize “the induction output 
                                        time” and “the blocking time” both gap 
                                        work, may apply in the gap survey product; 
                                        Simultaneously this function may effectively 
                                        suppress each kind of disturbance which 
                                        in the load cut process produces.(This 
                                        time may establish in zero several seconds―Several 
                                        dozens seconds) . | 
                                    
                                     
                                      | Trigger mode: continuous trigger, 
                                        non-continuous trigger (jumper select) | 
                                    
                                     
                                      | Electrical 
                                        parameter: | 
                                    
                                     
                                       
                                          
                                             
                                              |   Induction 
                                                  way  | 
                                                Passive 
                                                  form  | 
                                                Working 
                                                  voltage  | 
                                               3.3V-4.5VDC (other 
                                                voltages can be customized) | 
                                             
                                             
                                              |   Induction 
                                                  principle  | 
                                                Human body 
                                                  infrared  | 
                                                Biggest power 
                                                  loss  | 
                                                <0.00005W  | 
                                             
                                             
                                              Induction 
                                                  distance  | 
                                              3-5 meters  | 
                                              Output way  | 
                                              3.3V High 
                                                  level/low level  | 
                                             
                                             
                                              Induction 
                                                  angle  | 
                                              120 degrees 
                                                  coning angles  | 
                                              Load scope  | 
                                               | 
                                             
                                             
                                              The light 
                                                  controls the induction  | 
                                              5LUX-500LUX 
                                                  (adjustable) (standard controls 
                                                  function without light)  | 
                                              Ambient 
                                                  temperature  | 
                                              -20℃—+50℃  | 
                                             
                                          
                                          | 
                                    
                                     
                                      | Applicable 
                                        scope: | 
                                    
                                     
                                      |     
                                        Digital photo frame, advertising and other 
                                        types of electrical automatic control 
                                        and other functions, can be used for security 
                                        and other purposes. | 
                                    
                                     
                                      | Wiring graphical 
                                        representation: | 
                                    
                                     
                                      |   Red 
                                          wire to positive power supply, black 
                                          wire to negative one, the yellow line 
                                          high output   | 
                                    
                                     
                                      | Induction 
                                        scope graphical representation: | 
                                    
                                     
                                       
                                          
                                             
                                               
                                                   
                                                  (Wall installs graphical 
                                                  representation)   | 
                                                    | 
                                                
                                                (Attracts 
                                                  goes against installs graphical 
                                                  representation) 
                                                  | 
                                             
                                          
                                         
                                             
                                              
                                           
  |